Hormann Sectional Door Standards

01926 463 888


Tested and Certificated

Hormann Sectional Door Standards

All Hormann door products are tested and certified before being sold in the UK and Europe. The Hormann brand quality down to the smallest detail makes all the diference and ensures your safety. You do want to enjoy your door for a long time to come, after all. This is why Hormann's sectional doors fulfil the strictest standards with thoroughly convincing values. The quality is unquestionably one of the highest for this type of garage door and ease of installation is guaranteed as all panels are predrilled ready for the brackets and other components unlike other sectional doors.

Hormann doors offer thermal insulation, acoustic insulation, protection against wind pressure and tightness and sealing. At Hormann, the four performance characteristics relevant for garage doors are tested and certified. These are important for your choice of door over and above the mandatory safety reuirements. For example; thermal and sound insulaton for the garage, sealing against the adverse weather effects and resistant to wind pressure in particularly windy regions.

Thermal Insulation
Double-skinned steel doors 42/20mm
Section U=1.00 W/m²K
Door Leaf U=1.36 W/m²K
Fitted Door¹ U=1.80 W/m²K
Double-skinned steel doors 42mm
Section U=0.50 W/m²K
Door Leaf U=0.90 W/m²K
Fitted Door¹ U=1.30 W/m²K
Single-skinned steel doors
Door Leaf U=6.00 W/m²K
Fitted Door¹ U=6.40 W/m²K
Doors with solid timber infill
Door Leaf U=2.50 W/m²K
Fitted Door¹ U=2.90 W/m²K
   
Acoustic Insulation
Single-skinned steel doors R=approx. 20dB
Double-skinned steel doors 42/20mm R=approx. 21dB
Double-skinned steel doors 42mm R=approx. 22dB
   
Tightness and Sealing
Air  
Single-skinned steel doors Class 0
Double-skinned steel doors, ribbed (not L-ribbed) Class 2
Double-skinned steel doors, panelled and L-ribbed Class 3
Doors with solid timber infill Class 0*
Water  
Single-skinned steel doors Class 0
Double-skinned steel doors Class 3**
Doors with solid timber infill Class 0*
*Doors with ventilation slots, on request classes 2-3
** up to 70 Pa water pressure
 
Wind Pressure
Single-skinned steel doors Class 2
Double-skinned steel doors 42/20mm Class 3
Double-skinned steel doors 42mm Class 3
Doors with solid timber infill Class 3
Higher wind pressure classes on request
 
¹The U-values apply to fitted doors with a door area of 10m² without glazing

 

TRUSTED BRAND QUALITY  
ADVANTAGES OF A SECTIONAL GARAGE DOOR  
MARKET LEADING INNOVATIONS  
STANDARD OR PURPOSE MADE SIZES  
CHOOSE YOUR FINISH  
CHOOSE YOUR DESIGN  
DOOR DESIGN OVERVIEW  
CHOOSE YOUR COLOUR  
CLEAR VISION FROM HORMANN  
HANDLES AND ACCESSORIES  
REMOTE CONTROL OPERATION  
HORMANN SAFETY AS STANDARD  
TECHNICAL DATA

 Hormann sectional garage door

We use cookies to provide you with a better website experience. Close this popup to carry on browsing, or click here to find out more about cookies